RayView X-Ray for Busbar Insulation Thikness Measurement· Measure insulation thickness at 6 points. · Can measure single or multilayer of plastics with different densities,including wire insulating materials,sheaths,inner and outer semiconductive shielding layer,and pipe wall thickness. · The autonatic center height adjustment function ensures that cables pass through the center of the hole,preventing any contact with the cable edges. · No calibration required while device is operating. · Equipped with remote display and computer data acquisition functions for convenient analysis of production data.
Collect
Key Features
· Measure insulation thickness at 6 points. · Can measure single or multilayer of plastics with different densities,including wire insulating materials,sheaths,inner and outer semiconductive shielding layer,and pipe wall thickness. · The automatic center height adjustment function ensures that cables pass through the center of the hole,preventing any contact with the cable edges. · No calibration required while device is operating. · Equipped with remote display and computer data acquisition functions for convenient analysis of production data. Technical Parameters
Model:RayView-5050 Dia.Range:2-50 Accuracy:10 Scan Rate:10 times/second Comm. Interface:RS 485 Modbus or Profinet Power Supply:100 -240 VAC+ 10%,50/60 Hz,1,000W Dimensions (LxWxH, mm):1000x500x1300 |